Model NO.:
PI500-C
Contact Us
inverter@powtran.com
0411-8482088
Detailed introduction

PI500-C series air compressor frequency inverter is desiged for screw air compressor process control by Powtran Technology.The controparameters are set directly through the keyboard of frequency inverter or touch screen,both the Chinese and English interface are available.The frequency inverter can realizes all the functions required by screw air compressor,simple and convenient operation,compact size with more powerful function,it can control the permanent magnet synchronous motor and asynchronous motor air compressor.
The PI500-C series frequency inverter was sucessfully used for the screw air compressor ,it provides a more cost-effective way for the air compressor system,a variety of options,streamline the control system to reduce air compressor fault,but also provides a more convenient one-stop service,so that the installation and maintenance of screw air compressor become easy and fast.





Standard Specification
| Item | Function | Specification | |
| Power Input | Rated Voltage Level | AC IPH 220V(-15%)~240V(+10%) AC 3PH 220V(-15%~240V(+10%) AC 3PH 380V(-15%)-440V(+10%) | |
| Input Frequency | 50Hz/60Hz | ||
| Allowable Fluctuation | Voltage Continued Volatility±10% Input Frequency Volatility:5% Voltage Unhalance Rate Less Than 3% Distortion Meet lec 61800-2 Standard | ||
| Control System | Control system | High performance vector control inverter based on DSP | |
| Control method | V/F control,vector control W/O PG,vector contral W/PG | ||
| Acceleration/deceleration control | Straight or S-curve mode.Four times available and time range is 0.0 to 6500.0s. | ||
| Over load capability | G type:rated current 150-1 min,rated current 180%-3S | ||
| Maximum frequency | Vector control:0-500Hz | ||
| Carrier Frequency | 2-8kHZ;automatically adjust carrier frequency acconding to the load characteristics. | ||
| Input frequency resolution | Digital setting: 0.01Hz minimam analog amount:0.01Hz | ||
| Start torque | No PG vector control: 2% of rated speed 100% rated torque Vector control with PG:0hz/180% rted torque | ||
| Speed range | 1:50 (vector control W/O PG) 1:1000(vector contrel W/PG) | ||
| Steady-speed precision | Vector control W/O PG: ≤ 10.1% (rated synchromous speed) Vector control W/PG: a0.02% (rated synchronous speed) | ||
| Torque response | ≤40ms(vector control W/O PG) | ||
| Jogging control | Jog Frequency Range: 0.00Hz to max. frequency;Jog Ac/deceleration time:0.0s-6500.0s | ||
| Multi-speed operation | Achieve up to 16-spced operation through the control terminal | ||
| Buili-in PID | Easy to realize closed-loop control system for the process control. | ||
| Automatic voltage regulation(AVR) | Automatically maintain a constant output volage when the vollage of electricity grid changes | ||
| Torque limit and control | "Excavator" feature-torque is automatically limited during the operation to prevent frequent overcurrent trip:the closed-loop vector mode is used to control torque. | ||
| Persona-lization function | Self-inspection of peripherals after power-on | After powering on,peripheral equipment will perform safety testing, such as ground,short cireuit,etc. | |
| Rapid flow rate | The current limiting algorithmn is used to reduce the inverter overcurrent probability. and improve whole unit anti-interference capability. | ||
| Timing control | Timing control function:time setting range(0h to 6500m). | ||
| Running | Input signal | Running method | Keyboard/terminal/communication |
| Frequeny setting | 10 frequency setting available, incleding adjustable DC 0-10V/-10-+10V, adjustable DC 0-20mA,panel potentiometer | ||
| Start signal | Rotate forward/reverse | ||
| Multi-speed | At most 16-speed can be set(run by using the multi-function terminals or program) | ||
| Emergency stop | Interrupt controller output | ||
| Wobbulate run | Process controlrun | ||
| Fault reset | When the protection function is active, you can automatically or manually reset the fault condition. | ||
| Output signal | Ruaning status | Motor status display,stop,ac/doceleration,comstant spood,program rumming status. | |
| Faak output | Contact capacity: normal-closed coatact 3A/AC 250V;normal-opened contact 5A/AC250V;1A/DC 30V. | ||
| Analog output | Two-way analog output, 16 signals can be selected such as frequency,current,voltage and other, output signal range(0 to 10V/0to 20mA). | ||
| Output signal | At most 4-way output,there are 40 signals each way | ||
| Run function | Limit frequencyjump frequency,frequency compensation,auto-tuning,PID control | ||
| Running command channel | Three channels:operation pancl,control terminals and serial commumication port. They can be switchedthrough a variety of ways. | ||
| Frequency source | Total 10 frequency sources:digital,analog voltage,analog current,multi-peed and serial port. They can be switched througha variety of ways. | ||
| Input terminals | 8 digital input terminals,compatible with active PNP or NPN input mode,one of them can be for high-speedpulse input(0-100Hz square wave); 3 analog output terminals,Al1 and A12 can choose 0~10V or 0~20mA input,A13 voltage is-10~+10V input. | ||
| Output terminals | 2 digital output terminals,one of them can be for high-speed pulse output(0 to 100kHz square wave); one relay output terminal; 2 analog output terminals respectively for optional range (0to20mA or 0 to 10V),they can be used to set frequency,output frequency,speed and other physicalparameters. | ||
| Protection function | Inverter protection | Overvoltage protection,undervoltage protection,overcurrent protection,overload protection,overheat protection,overcurreat stall protection.overvoltage stall protection. losting-phase protection(optional).external fault,communication error,PID feedback signal abnormalitics,PG failure and short circuit to ground protection. | |
| IGBT temperature display | Displays cument temperature IGBT | ||
| Inverter fan control | Can be set | ||
| Parameter protection function | Protect inverter parameters by setting administrator Password and decoding | ||
| Display | LED/OLED display keyboard | Running information | Monitoring objects including:running frequency,set frequency,actual motor current,DC bus voltage,output voltage,ctual motor speed,cumulative running time,IGBT temperature, PID reference value,PID feedback value,input terminal status,output terminal status, analog AII value,analog A12 value,current stage of multi-speed,torque set value. |
| Error message | At most save 3 error message,and the time,type,voltage,current,frequency and work status can be queried when the failure is occurred. | ||
| LED display | Display parameters | ||
| OLED display | Optional, prompts operation content in Chinese English text. | ||
| Parameters copy | Cam uploading or downloading the function code information of frequency inverters,dothe parameter copy quickly. | ||
| Key leck and function selcction | Implement part or all of the key lock,define the scope of some buttons, in order to prevent wrong operation | ||
| Communication | RS485 | Built in 485 | |
| Environment | Environment temperature | -10℃ to 40'C (temperature at 40 'C to 50'C, please derating for use) | |
| Storage temperature | -20℃to65℃ | ||
| Environment humidity | Does not exceed 90% R.H, no condensation of moisture | ||
| Vibration | Below 5.9m/s'(-0.6g) | ||
| Application sites | Indoor where no sunlight or corrosive,explosive gas and water vapor,dust,flammahle gas, oil mist,water vapor,drip or salt,ete. | ||
| Altitude | Less than 1000 m normal use,the area of more than 1000 m,please accordingto 1% of the 100m deruting derating use. | ||
| Pollution degree | 2 | ||
| IP dogree | IP20 | ||
| Product standard | Product adopts safety standards. | IEC61800-5-1:2007 | |
| Product adopts EMC standards. | IEC61800-3:2005 | ||
| Cooling method | Forced air cooling | ||
PI500-C is special powtran inverter,it's mainly used in screw air compressor,we have professional engineer ,if you have any question welcome contact me.