Model NO.:

PI500-C

PI500-C series air compressor frequency inverter is desiged for screw air compressor process control by Powtran Technology.The controparameters are set directly through the keyboard of frequency inverter or touch screen,both the Chinese and English interface are available.The frequency inverter can realizes all the functions required by screw air compressor,simple and convenient operation,compact size with more powerful function,it can control the permanent magnet synchronous motor and asynchronous motor air compressor.
Powtran air compressor inverter
Powtran air compressor inverter
Powtran air compressor inverter
Powtran air compressor inverter
+
  • Powtran air compressor inverter
  • Powtran air compressor inverter
  • Powtran air compressor inverter
  • Powtran air compressor inverter

Contact Us

inverter@powtran.com

0411-8482088


Detailed introduction

 

PI500-C series air compressor frequency inverter is desiged for screw air compressor process control by Powtran Technology.The controparameters are set directly through the keyboard of frequency inverter or touch screen,both the Chinese and English interface are available.The frequency inverter can realizes all the functions required by screw air compressor,simple and convenient operation,compact size with more powerful function,it can control the permanent magnet synchronous motor and asynchronous motor air compressor.

The PI500-C series frequency inverter was sucessfully used for the screw air compressor ,it provides a more cost-effective way for the air compressor system,a variety of options,streamline the control system to reduce air compressor fault,but also provides a more convenient one-stop service,so that the installation and maintenance of screw air compressor become easy and fast.

 

 

Standard Specification

ItemFunctionSpecification
Power InputRated Voltage LevelAC IPH 220V(-15%)~240V(+10%)     
AC 3PH 220V(-15%~240V(+10%)     
AC 3PH 380V(-15%)-440V(+10%)
Input Frequency50Hz/60Hz
Allowable FluctuationVoltage Continued Volatility±10% Input Frequency Volatility:5%     
Voltage Unhalance Rate Less Than 3% Distortion Meet lec 61800-2 Standard
Control SystemControl systemHigh performance vector control inverter based on DSP
Control methodV/F control,vector control W/O PG,vector contral W/PG
Acceleration/deceleration controlStraight or S-curve mode.Four times available and time range is 0.0 to 6500.0s.
Over load capabilityG type:rated current 150-1 min,rated current 180%-3S
Maximum frequencyVector control:0-500Hz
Carrier Frequency2-8kHZ;automatically adjust carrier frequency acconding to the load characteristics.
Input frequency resolutionDigital setting: 0.01Hz minimam analog amount:0.01Hz
Start torqueNo PG vector control: 2% of rated speed 100% rated torque     
Vector control with PG:0hz/180% rted torque
Speed range1:50 (vector control W/O PG) 1:1000(vector contrel W/PG)
Steady-speed precisionVector control W/O PG: ≤ 10.1% (rated synchromous speed)     
Vector control W/PG: a0.02% (rated synchronous speed)
Torque response≤40ms(vector control W/O PG)
Jogging controlJog Frequency Range: 0.00Hz to max. frequency;Jog Ac/deceleration time:0.0s-6500.0s
Multi-speed operationAchieve up to 16-spced operation through the control terminal
Buili-in PIDEasy to realize closed-loop control system for the process control.
Automatic voltage regulation(AVR)Automatically maintain a constant output volage when the vollage of electricity grid changes
Torque limit and control"Excavator" feature-torque is automatically limited during the operation to prevent frequent     
overcurrent trip:the closed-loop vector mode is used to control torque.
Persona-lization functionSelf-inspection of peripherals     
after power-on
After powering on,peripheral equipment will perform safety testing, such as ground,short cireuit,etc.
Rapid flow rateThe current limiting algorithmn is used to reduce the inverter overcurrent probability.     
and improve whole unit anti-interference capability.
Timing controlTiming control function:time setting range(0h to 6500m).
RunningInput signalRunning methodKeyboard/terminal/communication
Frequeny setting10 frequency setting available, incleding adjustable DC 0-10V/-10-+10V,     
adjustable DC 0-20mA,panel potentiometer
Start signalRotate forward/reverse
Multi-speedAt most 16-speed can be set(run by using the multi-function terminals or program)
Emergency stopInterrupt controller output
Wobbulate runProcess controlrun
Fault resetWhen the protection function is active, you can automatically or manually reset the fault condition.
Output signalRuaning statusMotor status display,stop,ac/doceleration,comstant spood,program rumming status.
Faak outputContact capacity: normal-closed coatact 3A/AC 250V;normal-opened contact 5A/AC250V;1A/DC 30V.
Analog outputTwo-way analog output, 16 signals can be selected such as frequency,current,voltage and other,     
output signal range(0 to 10V/0to 20mA).
Output signalAt most 4-way output,there are 40 signals each way
Run functionLimit frequencyjump frequency,frequency compensation,auto-tuning,PID control
Running command channelThree channels:operation pancl,control terminals and serial commumication port.     
They can be switchedthrough a variety of ways.
Frequency sourceTotal 10 frequency sources:digital,analog voltage,analog current,multi-peed and serial port.     
They can be switched througha variety of ways.
Input terminals8 digital input terminals,compatible with active PNP or NPN input mode,one of them     
can be for high-speedpulse input(0-100Hz square wave); 3 analog output terminals,Al1     
and A12 can choose 0~10V or 0~20mA input,A13 voltage is-10~+10V input.
Output terminals2 digital output terminals,one of them can be for high-speed pulse output(0 to 100kHz     
square wave); one relay output terminal; 2 analog output terminals respectively for     
optional range (0to20mA or 0 to 10V),they can be used to set frequency,output     
frequency,speed and other physicalparameters.
Protection functionInverter protectionOvervoltage protection,undervoltage protection,overcurrent protection,overload     
protection,overheat protection,overcurreat stall protection.overvoltage stall protection.     
losting-phase protection(optional).external fault,communication error,PID feedback     
signal abnormalitics,PG failure and short circuit to ground protection.
IGBT temperature displayDisplays cument temperature IGBT
Inverter fan controlCan be set
Parameter protection functionProtect inverter parameters by setting administrator Password and decoding
DisplayLED/OLED     
display     
keyboard
Running     
information
Monitoring objects including:running frequency,set frequency,actual motor current,DC     
bus voltage,output voltage,ctual motor speed,cumulative running time,IGBT temperature,     
PID reference value,PID feedback value,input terminal status,output terminal status,     
analog AII value,analog A12 value,current stage of multi-speed,torque set value.
Error messageAt most save 3 error message,and the time,type,voltage,current,frequency and work     
status can be queried when the failure is occurred.
LED displayDisplay parameters
OLED displayOptional, prompts operation content in Chinese English text.
Parameters copyCam uploading or downloading the function code information of frequency inverters,dothe parameter copy quickly.
Key leck and function selcctionImplement part or all of the key lock,define the scope of some buttons, in order to prevent wrong operation
CommunicationRS485Built in 485
EnvironmentEnvironment temperature-10℃ to 40'C (temperature at 40 'C to 50'C, please derating for use)
Storage temperature-20℃to65℃
Environment humidityDoes not exceed 90% R.H, no condensation of moisture
VibrationBelow 5.9m/s'(-0.6g)
Application sitesIndoor where no sunlight or corrosive,explosive gas and water vapor,dust,flammahle gas,     
oil mist,water vapor,drip or salt,ete.
AltitudeLess than 1000 m normal use,the area of more than 1000 m,please accordingto 1% of the 100m     
deruting derating use.
Pollution degree2
IP dogreeIP20
Product standardProduct adopts safety standards.IEC61800-5-1:2007
Product adopts EMC standards.IEC61800-3:2005
Cooling methodForced air cooling