PMSM special used inverter
PMSM special used inverter
PMSM special used inverter
PMSM special used inverter
+
  • PMSM special used inverter
  • PMSM special used inverter
  • PMSM special used inverter
  • PMSM special used inverter

Keywords

PMSM special used inverter

Model NO.:

PI500-E

PI500-E permanent magnet synchronous frequency inverter is known to science and technology based on motor operation and control,new research and development of a permanent magnet synchronous frequency inverter .Achieved high performance,high quality,small size installation area,design of high power density,high efficiency,energy saving,small startup current,high return Big start torque,low control accuracy is high ,the motor temperature rise ,its rich functions,application is simple , the advantages of stable performance more flexible the user`s experience.
PMSM special used inverter
PMSM special used inverter
PMSM special used inverter
PMSM special used inverter
+
  • PMSM special used inverter
  • PMSM special used inverter
  • PMSM special used inverter
  • PMSM special used inverter

Contact Us

inverter@powtran.com

0411-8482088


Detailed introduction

 PI500-E permanent magnet synchronous frequency inverter is known to science and technology based on motor operation and control,new research and development of a permanent magnet synchronous frequency inverter .Achieved high performance,high quality,small size installation area,design of high power density,high efficiency,energy saving,small startup current,high return Big start torque,low control accuracy is high ,the motor temperature rise ,its rich functions,application is simple , the advantages of stable performance more flexible the user`s experience.

 

Standard Specification

ItemFunctionSpecification
Power InputRated Voltage LevelAC IPH 220V(-15%)~240V(+10%)    
AC 3PH 220V(-15%~240V(+10%)    
AC 3PH 380V(-15%)-440V(+10%)
Input Frequency50Hz/60Hz
Allowable FluctuationVoltage Continued Volatility±10% Input Frequency Volatility:5%    
Voltage Unhalance Rate Less Than 3% Distortion Meet lec 61800-2 Standard
Control SystemControl systemHigh performance vector control inverter based on DSP
Control methodV/F control,vector control W/O PG,vector contral W/PG
Acceleration/deceleration controlStraight or S-curve mode.Four times available and time range is 0.0 to 6500.0s.
Over load capabilityG type:rated current 150-1 min,rated current 180%-3S
Maximum frequencyVector control:0-500Hz
Carrier Frequency2-8kHZ;automatically adjust carrier frequency acconding to the load characteristics.
Input frequency resolutionDigital setting: 0.01Hz minimam analog amount:0.01Hz
Start torqueNo PG vector control: 2% of rated speed 100% rated torque    
Vector control with PG:0hz/180% rted torque
Speed range1:50 (vector control W/O PG) 1:1000(vector contrel W/PG)
Steady-speed precisionVector control W/O PG: ≤ 10.1% (rated synchromous speed)    
Vector control W/PG: a0.02% (rated synchronous speed)
Torque response≤40ms(vector control W/O PG)
Jogging controlJog Frequency Range: 0.00Hz to max. frequency;Jog Ac/deceleration time:0.0s-6500.0s
Multi-speed operationAchieve up to 16-spced operation through the control terminal
Buili-in PIDEasy to realize closed-loop control system for the process control.
Automatic voltage regulation(AVR)Automatically maintain a constant output volage when the vollage of electricity grid changes
Torque limit and control"Excavator" feature-torque is automatically limited during the operation to prevent frequent    
overcurrent trip:the closed-loop vector mode is used to control torque.
Persona-lization functionSelf-inspection of peripherals    
after power-on
After powering on,peripheral equipment will perform safety testing, such as ground,short cireuit,etc.
Rapid flow rateThe current limiting algorithmn is used to reduce the inverter overcurrent probability.    
and improve whole unit anti-interference capability.
Timing controlTiming control function:time setting range(0h to 6500m).
RunningInput signalRunning methodKeyboard/terminal/communication
Frequeny setting10 frequency setting available, incleding adjustable DC 0-10V/-10-+10V,    
adjustable DC 0-20mA,panel potentiometer
Start signalRotate forward/reverse
Multi-speedAt most 16-speed can be set(run by using the multi-function terminals or program)
Emergency stopInterrupt controller output
Wobbulate runProcess controlrun
Fault resetWhen the protection function is active, you can automatically or manually reset the fault condition.
Output signalRuaning statusMotor status display,stop,ac/doceleration,comstant spood,program rumming status.
Faak outputContact capacity: normal-closed coatact 3A/AC 250V;normal-opened contact 5A/AC250V;1A/DC 30V.
Analog outputTwo-way analog output, 16 signals can be selected such as frequency,current,voltage and other,    
output signal range(0 to 10V/0to 20mA).
Output signalAt most 4-way output,there are 40 signals each way
Run functionLimit frequencyjump frequency,frequency compensation,auto-tuning,PID control
Running command channelThree channels:operation pancl,control terminals and serial commumication port.    
They can be switchedthrough a variety of ways.
Frequency sourceTotal 10 frequency sources:digital,analog voltage,analog current,multi-peed and serial port.    
They can be switched througha variety of ways.
Input terminals8 digital input terminals,compatible with active PNP or NPN input mode,one of them    
can be for high-speedpulse input(0-100Hz square wave); 3 analog output terminals,Al1    
and A12 can choose 0~10V or 0~20mA input,A13 voltage is-10~+10V input.
Output terminals2 digital output terminals,one of them can be for high-speed pulse output(0 to 100kHz    
square wave); one relay output terminal; 2 analog output terminals respectively for    
optional range (0to20mA or 0 to 10V),they can be used to set frequency,output    
frequency,speed and other physicalparameters.
Protection functionInverter protectionOvervoltage protection,undervoltage protection,overcurrent protection,overload    
protection,overheat protection,overcurreat stall protection.overvoltage stall protection.    
losting-phase protection(optional).external fault,communication error,PID feedback    
signal abnormalitics,PG failure and short circuit to ground protection.
IGBT temperature displayDisplays cument temperature IGBT
Inverter fan controlCan be set
Parameter protection functionProtect inverter parameters by setting administrator Password and decoding
DisplayLED/OLED    
display    
keyboard
Running    
information
Monitoring objects including:running frequency,set frequency,actual motor current,DC    
bus voltage,output voltage,ctual motor speed,cumulative running time,IGBT temperature,    
PID reference value,PID feedback value,input terminal status,output terminal status,    
analog AII value,analog A12 value,current stage of multi-speed,torque set value.
Error messageAt most save 3 error message,and the time,type,voltage,current,frequency and work    
status can be queried when the failure is occurred.
LED displayDisplay parameters
OLED displayOptional, prompts operation content in Chinese English text.
Parameters copyCam uploading or downloading the function code information of frequency inverters,dothe parameter copy quickly.
Key leck and function selcctionImplement part or all of the key lock,define the scope of some buttons, in order to prevent wrong operation
CommunicationRS485Built in 485
EnvironmentEnvironment temperature-10℃ to 40'C (temperature at 40 'C to 50'C, please derating for use)
Storage temperature-20℃to65℃
Environment humidityDoes not exceed 90% R.H, no condensation of moisture
VibrationBelow 5.9m/s'(-0.6g)
Application sitesIndoor where no sunlight or corrosive,explosive gas and water vapor,dust,flammahle gas,    
oil mist,water vapor,drip or salt,ete.
AltitudeLess than 1000 m normal use,the area of more than 1000 m,please accordingto 1% of the 100m    
deruting derating use.
Pollution degree2
IP dogreeIP20
Product standardProduct adopts safety standards.IEC61800-5-1:2007
Product adopts EMC standards.IEC61800-3:2005
Cooling methodForced air cooling

 

Inverter modelOutput power  
(kW)
Input current  
(A)
Output current  
(A)
Dimension(HIxWxD1mm)Installation(AxB dm)N.W  
(KG)
HH1WDD1ABd
PI500-E 5R5G15.5502528030019019019814028567.2
PI500-E 5R5G25.5282528030019019019814028567.2
PI500-E 7R5G27.537.132
PI500-E 011G21149.84533035021019019815033569.5
PI500-E 015G21565.460380400240215223180385713
PI500-E 018G218.581.675
PI500-E 022G22297.7905005203002752832205001041.2
PI500-E 030G230122.1110
PI500-E 037G237157.4152
PI500-E 045G245185.31765505753553203282505551058
PI500-E 055G255214210
PI500-E 075G2753073046957204003603683007001072.5
PI500-E 0R7G30.754.32.1163185901461546517451.6
PI500-E 1R5G31.553.8
PI500-E 2R2G32.25.85.1
PI500-E 004G3410.59163185901661746517451.8
PI500-E 5R5G35.514.6132382601201821909025052.7
PI500-E 7R5G37.520.517
PI500-E 011G311262528030019019019814028567.2
PI500-E 015G3153532
PI500-E 018G318.538.53733035021019019815033569.5
PI500-E 022G32246.545
PI500-E 030G3306260380400240215223180385713
PI500-E037G3377675
PI500-E 045G34591905005203002752832205001041.2
PI500-E 055G355112110
PI500-E 075G375157152
PI500-E 090G3901801765505753553203282505551058
PI500-E 110G3110214210
PI500-E 132G31322562536957204003603683007001072.5
PI500-E 160G316030730479082048039039837080011108
P1500-E 200G3200385380
PI500-E 220G3220430426
PI500-E 250G325046846594098070541041855094513190
PI500-E 280G3280525520
PI500-E 315G3315590585
PI500-E 355G3355665650
PI500-E 400G3400785725
PI500-E 132G3R132256253995102040036036835027013*18114.5
PI500-E 160G3R1603073041230126048039039840020013153
P1500-E 200G3R200385380
PI500-E 220G3R220430426
PI500-E 250G3R2504684651419146070541041862024013249.4
PI500-E 280G3R280525520
PI500-E 315G3R315590585
PI500-E 355G3R355665650

 

PI500-E is special application Powtran inverter,if you have interests welcome contact me.

Request a quote now

Attention: Please leave your contact information, and our specialists will get in touch with you as soon as possible!

Submit a message

Related Downloads

File name

Version

Format

File size

Date

Download

PI500-E series PMSM special used inverter manual

EV1.0

pdf

6.3MB

2025-12-18